Filter Results By:

Products

Applications

Manufacturers

Time Interval

a moment of time.

See Also: Time, Timers, GPS Time, Time Reference, Time Code, Time Domain, Time Standards, Timing


Showing results: 91 - 95 of 95 items found.

  • Electronic Multifunction Data Loggers

    DeltaTRAK

    The DeltaTrak Electronic Data Logger is a portable, pocket sized electronic device powered by a 10-year lithium battery. It is designed for easy and reliable tracking of parameters such as temperature, relative humidity, electric current, pressure, process signals, and pulse signals. All data loggers have a built-in temperature sensor plus single or multiple external channels where different sensors can be attached for remote monitoring of a variety of parameters. The DeltaTrak Data Loggers interface with a PC and have an internal memory for up to 32,000 readings. Each data point is automatically time and date stamped as it is recorded. Sampling intervals are set by the operator via a user-friendly Windows program on the PC. Recorded data is downloaded and graphed or exported in ASCII format to a spreadsheet for numerical print outs.

  • High-Speed Video Camera

    Hyper Vision HPV-X2 - Shimadzu Corp.

    Medical science and engineering have made dramatic progress thanks to visualization technology. Examples include the invention of microscopes capable of enlarged observations of phenomena occurring in the microscopic domain, invisible to the human eye, X-ray inspection systems, which enable the observation of images utilizing light at imperceptible wavelengths, and infrared cameras. Our eyes are incapable of capturing phenomena occurring at times shorter than 50 to 100 ms. As a result, high-speed video cameras have become necessary in order to record phenomena occurring at intervals that cannot be seen with the human eye, and then replay them at a slower rate so that they can be visualized. As the standard tool for visualizing ultra high-speed domains, the Hyper Vision high-speed video camera contributes to our understanding of ultra high-speed phenomena in a variety of fields.

  • High Accuracy Spectrophotocolorimeter

    LMS-3000 - Lisun Electronics Inc.

    • Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃

  • pH 2700 Benchtop Meters

    OAKTON Instruments

    Oakton 2700 meters meet GLP requirements - meters stamp all calibration and stored data with time/date. Nonvolatile memory stores up to 500 data sets to simplify documenting large volumes of pH or mV measurements. Meters automatically calculate and display electrode slope and offset - ideal for checking electrode quality. Order RS-232 and optional RS-232 to USB adapter separately. Advanced set-up options allow for a large degree of user customization. Datalogging intervals can be programmed into the meter for convenient continuous monitoring. Programmable limit alarm alerts you when readings fall out of range. Calibrate up to 6 points for pH using USA, NIST, DIN, or custom buffer sets. Optional password protection prevents changes to meter setup and calibration. Oversized 3-1/4" x 2-7/16" (8.3 x 6.2 cm) graphic LCD can be viewed from across the room. Bright backlight and large digits allow readings in all conditions. Informative display shows pH or Redox measurements together with temperature, electrode status, cal points, time and date all at once! Cal-due alarm lets you know when recalibration is necessary for measurement accuracy. Visual stability indicator informs you when measurements have stabilized, eliminating guesswork. Comprehensive self-diagnostics make troubleshooting a breeze.

  • Multifunction Electrical Installations Meter

    MPI-525 - Sonel S.A.

    Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.

Get Help